SmartZone Failsoft Inactivity

(Trunking Wide, Advanced)

HGDefinitionMob%26Port.jpg

Selects the amount of Failsoft Mode inactivity time that determines when the radio attempts to search for a valid and active control channel. This timer begins once all Failsoft receive and transmit communications have ceased; if the timer expires before any Failsoft communications occur, the radio begins searching for an available control channel. If communications do occur during this timer period, the timer is reset. This selection applies when in SmartZone operation for all Trunking Systems and Trunking Personalities. Time is in seconds.

HGAccessedOnly.jpg

When the radio is model / option capable.

HGSelections.jpg

Minimum

Maximum

0 seconds

255 seconds

GoArrow.jpg

Go to the Advanced Page